SEDEX 80 LT-ELSD detector (HPLC)

Information
Detector_ELSD-Sedex.jpg click to zoom Catalog No.: SED80000


HPLC nebulizer, without RS232

Description

ELSD detectors are univerzal detectors which measures sample particles after solvent evaporation by using scattered light. This kind of detection is independent of optical properties of sample in contrast to UV detection. Analyte must be lower volatile than solvent. It is possible to detect compounds without chromophores like: saccharides, lipids, polymers, non-derivatized fat acids and amino acids, oils, surface active compounds, small molecules and unknown compounds whitout information about their structure. Response of detector is depending on quantity and it is mean that detector can be used for quantitative analysis without calibration. It can be used in gradient applications and it not depend on temperature in contrast of RI detectors.

Main features:

  • low evaporation temperature settings
  • choice of two nebulizers
  • easy validation and calibration
  • automated operations

Source of nebulizing gas is neccessary for detector operation. Air pressure can be used as nebulizing gas for non-explosive and on higher used temperature safe solvents (it can not be used for explosive THF and for solvents with higher fraction of organics). Air pressure can not be used for samples degrading by oxidation. Nitrogen is solution for other cases. Pressure cylinders can be used as gas source (expensive) or gas generators - see to accessories.

Next items is neccessary to order with detector: Gas regulator with filter and manometer for ELSD (for generator and pressure cylinder also).

This detector is equiped with HPLC nebulizer, but on request could be equiped with CC nebulizer see nebulizers flow-rates overview.

Specification

Technical parameters:

Parameter Value
Detection High Sensitivity PhotoMultiplier Tube
Light Source LED 470 nm (blue)
Eluent Flow-rate 0.1-2.5 ml/min.
Evaporative Temperature Range ambient - 100°C
Gas pressure: 3.5 bar (51 psi), flow-rate: less than 3 L/min.
Nebulizer HPLC (on request CC up to 5 ml/min.)
Analog output 0-1 V
Gain Setting 1 to 12, 211 (2048)
Data Rate 40 Hz
Filter 0-10 s (Moving Average)
Control Keypad and display, external interface
External interface Ready, Autozero, Powerdown
GLP Audit Trail - Password - Admin mode, All parameters real time recording
Powerdown modes Photomultiplier shut-off, Gas shut-off, Powerdown timer
Power Consuption 150 VA
Power Requirements 230 V, 50 Hz
Dimensions (š x v x d) 250 x 480 x 550 mm
Weight 18.5 kg
 