ECS04 Gradient Analytical System

10ml/min 40MPa 190-800
Highly effective HPLC system containing a UV-VIS detector, a column oven, an analytical pump, a gradient box, and an autosampler.
Availability
Categories
Manufacturer
ECOM spol. s r.o.
Part number
ASA0400X

Detector with continuously variable wavelength 190-800 nm and very low noise level offers high-speed sampling up to 100 Hz.

Communication of units is through RS232 or Ethernet(LAN). An additional PC A/D converter card is not required for this system. The system contains autosampler and Clarity software. All units are supported in Clarity software from installation.
 
A wireless mouse and keyboard set (P/N: EPC-0028), PC (P/N: EPC-0026) and a computer monitor (P/N: EPC-0027) can be purchased with the system.

Main parts

ECD2800 UV-VIS DETECTOR
Detector with a continuously variable wavelength in the range of 190-800  nm and a noise level ±3·10-6 AU. The unit offers high-speed sampling up to 100 Hz and wavelength autocalibration. AC 05 analytical cell is included.
 
ECO2080 COLUMN OVEN WITH HEATING  AND COOLING
This column oven allows precise temperature stabilization in the range of 0-80°C. A big compartment room can accommodate up to 3 columns with lengths up to 25 cm. Peltier technology offers the possibility of heating and cooling independently from room temperature.
 
ECP2010 ANALYTICAL HPLC PUMP
This isocratic pump works with Gradient Box ECB2004B as a quaternary gradient pump. The flow rate range is 0.02-10.00 ml/min and the pressure limit at 40 MPa. Unit software includes a new learning algorithm for pulsation suppression and many testing and diagnostic functions.
 
ECB2004B GRADIENT BOX WITH DEGASSER
The box is suited for handling liquids in ECOM gradient systems. It accommodates a container for solvent
bottles, a built-in high-efficiency vacuum degasser, and a four-way gradient valve. Up to four solvent lines may be degassed simultaneously by one unit. A four-way gradient valve is controlled from the pump ECP2010.
 
AUTOSAMPLER L-3320
The automatic autosampler ensures excellent accuracy and linearity of sample injection. Very low sample residue contamination, μl pick-up mode achieves zero sample loss. Automated self-checking. Rheodyne valve ensures reliable operation.
 
CLARITY CHROMATOGRAPHY SOFTWARE
This system is fully controlled by Clarity Chromatography software, which is also a part of delivery. Clarity software complies with CFR21GLP requirements.
 
SYSTEM CONTAINS
 
Pcs  Description  P/N 
 1 ECD2800 UV-VIS Detector  ADA0000X 
 1 ECB2004B Gradient box with degasser  ABA0000X
 1 ECP2010 Analytical HPLC pump  ACA0000X
 1 ECO2080 Column Oven with heating and cooling AOA0000X 
 1 Autosampler L3320 for 2x48 vials  ARA03320 
 1 Clarity – Station for 1 instrument AP000C50
 1 Clarity module for HPLC control  AP000A24 
Clarity SW module for AS control  AP000A26 
Accessories for analyt. system series 2000  ASA00180 
1 Accessories ECOM for AS Rigol L3320/L3320H ARA00180
 
Note: Column and computer are not included. PC system has to be equipped for handling 3 serial RS232 or 1 Ethernet port at least. Check also Clarity software requirements.