ECS01 Gradient Analytical System

10ml/min 40MPa 190-800

Highly effective HPLC system containing a UV-VIS detector, a column oven, an analytical pump, and a gradient box. The detector has a continuously variable wavelength of 190-800 nm and a very low noise level. It features high-speed sampling up to 100 Hz.

Availability
Categories
Manufacturer
ECOM spol. s r.o.
Part number
ASA0100X

Communication of all units is through RS232 or Ethernet (LAN). An additional PC A/D converter card is not required for this system.

The system contains a manual injector and  Clarity software. All units are supported in Clarity software from installation.

A wireless mouse, a keyboard set (P/N: EPC-0028), a PC (P/N: EPC-0026), and a computer monitor (P/N: EPC-0027) can be purchased with the system.

Main parts

ECD2800 UV-VIS DETECTOR
Detector with a continuously variable wavelength in the range of 190-800 nm and a noise level of ±3·10-6 AU. The unit offers high-speed sampling up to 100 Hz and wavelength autocalibration. AC 05 analytical cell is included.

 

ECO2080 COLUMN OVEN WITH HEATING AND COOLING
The Peltier heating/cooling column oven with a large space can hold up to 3 columns up to 25 cm long. An overheat safety fuse prevents destruction of temperature-sensitive columns.
 
ECP2010 ANALYTICAL HPLC PUMP
This isocratic pump works with the Gradient Box ECB2004B as a quaternary gradient pump. The flow rate range is 0.02-10.00 ml/min, and the pressure limit is 40 MPa. Unit software includes a new learning algorithm for pulsation suppression and many testing and diagnostic functions.
 
ECB2004B GRADIENT BOX WITH DEGASSER
The box is suited for handling liquids in ECOM gradient systems.
It accommodates a container for solvent bottles, a built-in high-efficiency vacuum degasser, and a four-way gradient valve. Up to four solvent lines may be degassed simultaneously by one unit. A four-way gradient valve is controlled from the pump ECP2010.
 
CLARITY CHROMATOGRAPHY SOFTWARE
This system is fully controlled by Clarity Chromatography software, which is also a part of the delivery. Clarity software complies with CFR21GLP requirements.

 

SYSTEM CONTAINS
Pcs Description P/N
1 ECD2800 UV-VIS Detector ADA0000X
1 ECB2004B Gradient box with degasser ABA0000X
1 ECP2010 Analytical HPLC pump ACA0000X
1 ECO2080 Column Oven AOA0000X
1 Clarity – Station for 1 instrument AP000C50
1 Clarity module for HPLC control AP000A24
1 Analytical/semipreparative injection valve 1/16" with 20ul sample loop and connector AVE02006
1 Accessories for analyt. system series 2000 ASA00180

 

Note: Column and computer are not included. The PC system has to be equipped for handling at least 3 serial RS232 or 1 Ethernet ports. Check also the Clarity software requirements.