ECDM2100 Conductivity and pH Monitors

ECDM 2100 are conductivity and pH monitors, used for preparative and flash chromatography

Availability
Manufacturer
ECOM spol. s r.o.
Choose variant:
Image PN Name Thread Tube OD Request quote
Image
Conductivity Monitor (1/16), CD0016XX, Thread UNF10 -32, Tube OD 1/16“
PN
CD0016XX
Name
Conductivity Monitor (1/16)
Thread
UNF 10-32
Tube OD
1/16“
Actions
Image
Conductivity Monitor (1/8), Thread ¼-28“, Tube OD 1/8“
PN
CD0018XX
Name
Conductivity Monitor (1/8)
Thread
UNF ¼-28“
Tube OD
1/8“
Actions
Image
Conductivity and pH Monitor - Without pH cell and sensor,1/16, Thread UNF10-32, Tube OD 1/16“
PN
CDPH16XX
Name
Conductivity and pH Monitor-Without pH cell and sensor, 1/16
Thread
UNF 10-32
Tube OD
1/16“
Actions
Image
Conductivity and pH Monitor - Without pH cell and sensor,1/8, Thread UNF ¼-28“, Tube OD 1/8“
PN
CDPH18XX
Name
Conductivity and pH Monitor-Without pH cell and sensor, 1/8
Thread
UNF ¼-28“
Tube OD
1/8“
Actions
Image
Conductivity and pH Monitor-Set with pH cell and sensor, Thread UNF10 -32, Tube OD 1/16“
PN
CDPHS16X
Name
Conductivity and pH Monitor-Set with pH cell and sensor, 1/16
Thread
UNF 10-32
Tube OD
1/16“
Actions
Image
Conductivity and pH Monitor-Set with pH cell and sensor, Thread UNF ¼-28“, Tube OD 1/8“
PN
CDPHS18X
Name
Conductivity and pH Monitor -Set with pH cell and sensor,1/8
Thread
UNF ¼-28“
Tube OD
1/8“
Actions

ECDM 2100 are conductivity and pH monitors suited for preparative and flash chromatography. Thanks to the unique ECOM design of the conductivity cell, it radically improves chromatography process monitoring.
The detector cells have been developed for high-pressure applications, which means they can be used in CaptureSMB applications. These applications utilize a twin-column periodic countercurrent (PCC) process used for the continuous purification of monoclonal antibodies.
The unit is controlled by a Beatrix22 printed board, which measures the conductivity of liquid passing through both the cell and the pH value.

Main features and benefits
• High-pressure cell up to 17 MPa
• Simple conductivity calibration
• Compact size
• Powered by 12 – 24 V
• Sophisticated diagnostic software

Conductivity Monitoring 0 – 300 mS/cm
Operating pressure 0-17 Mpa
Flow rate 0.01 – 200 mL/min
pH reading ranges 1-14 pH
Wetted materials Titan and PEEK
Communication RS232,Ethernet (LAN),USB
Power supply 12 - 24 V
Power input 2.5 W
Dimensions W x H x D 187 × 56 × 112 mm (7.36 × 2.20 × 4.40 in)
Weight 0.94 kg (2.07 Ib)
Cell connecting Tubing with OD 1/16″, thread UNF 10-32 , tubing with OD 1/8″, thread UNF 1/4-28″
Filename Type
Info-ECDM2100_monitor-en-00 pdf (240,46 KB)