ECDU2100 Conductivity, UV and pH Monitors
ECDU 2100 are conductivity, UV, and pH monitors, used for preparative and flash chromatography
Related variants
| Image | PN | Name | Thread | Tube OD | Request quote |
|---|---|---|---|---|---|
|
Image
|
PN
CDPU1600
|
Name
Conductivity, UV and pH Monitor-Without pH cell and sensor, 1/16
|
Thread
UNF 10-32
|
Tube OD
1/16“
|
Actions
|
|
Image
|
PN
CDPU1800
|
Name
Conductivity, UV and pH Monitor - Without pH cell and sensor,1/8
|
Thread
UNF ¼-28“
|
Tube OD
1/8“
|
Actions
|
|
Image
|
PN
HBIOA002
|
Name
pH sensor AURORA HBIO-A002
|
Thread
---
|
Tube OD
---
|
Actions
|
|
Image
|
PN
S450CD1
|
Name
pH sensor SENSOREX double-junction,
|
Thread
---
|
Tube OD
---
|
Actions
|
|
Image
|
PN
238801
|
Name
pH sensor Hamilton MecoTrode 120 REF238801
|
Thread
---
|
Tube OD
---
|
Actions
|
|
Image
|
PN
PHAS0800
|
Name
pH Flowcell for Hamilton pH Sensor (Connection with 1/8" or 1/16" Capillaries)
|
Thread
UNF ¼-28“
|
Tube OD
1/8" or 1/16"
|
Actions
|
|
Image
|
PN
PHBP0800
|
Name
pH Flowcell for Sensorex pH Sensor (Connection with 1/8" or 1/16" Capillaries)
|
Thread
UNF ¼-28“
|
Tube OD
1/8" or 1/16"
|
Actions
|
|
Image
|
PN
PHCS0800
|
Name
pH Flowcell for Aurora pH Sensor (Connection with 1/8" or 1/16" Capillaries)
|
Thread
UNF ¼-28“
|
Tube OD
1/8" or 1/16"
|
Actions
|
- Description
- Parameters
The ECDU 2100 is a conductivity and pH monitor, in addition equipped with a UV cell. These detectors are suited for preparative and flash chromatography. Thanks to the unique ECOM design of the dual UV and conductivity cell, it radically improves chromatography process monitoring.
The dual cell has been developed for high-pressure applications where it is necessary to measure conductivity and UV absorbance at the same time, without any delay. To achieve such requirements, the conductivity and UV cells are assembled in one block. Signal from the conductivity cell is evaluated using an electronic board which is inside this unit, signal from the UV cell is evaluated by means UV detector which is connected to the cell by optical cables. See: With optical connectors - EXTo measure pH, it is necessary to order a suitable pH probe and flow cell. The pH flow cell is connected in series downstream of the conductivity detector. The flow cell accessories include capillaries and fittings for both 1/16" and 1/8" versions.
Main features and benefits of this unit:
- High-pressure conductivity cell up to 17 MPa (for 1/16” version)
- High-pressure UV cell up to 30 MPa (OPL in range 0.1 – 2 mm)
- Simple conductivity calibration
- PH cell (choose the cell for the used PH sensor)
- Compact size
- Powered by 12 – 24 V DC
- Sophisticated diagnostic software
| Conductivity Monitoring | 0.01 – 300.0 mS/cm |
|---|---|
| Operating pressure | 0 – 17 MPa (0 – 2465.6 psi; 0 – 170.0 bar) |
| Communication | RS232 |
| Ethernet (LAN) | |
| USB | |
| Flow rate | Conductivity monitor-0.01 – 200 mL/min |
| pH reading ranges | 0.0-14.0 pH |
| Wetted materials | Titanium and PEEK (conductivity monitor) |
| Communication | RS232,Ethernet (LAN),USB |
| Power supply | 12 - 24 V DC |
| Power input | 2.5 W |
| Wavelengths | According used detector |
| Cell connecting | Tubing with OD 1/16″, thread UNF 10-32 , tubing with OD 1/8″, thread UNF 1/4-28″ |
| Dimensions W x H x D | 140 x 168 x 165 mm (5.51” x 6.61” x 6.46”) |
| Weight | 1.31 kg (2.89 lb) |
pH Flow Cells
PH Cells, are used for ECOM Conductivity and pH monitors.
| 1 Piece | €2.42 |
| 2 and more pieces | €0.00 |
Fiber-optic cables with SMA 905 connectors
Fiber-optic cables with SMA 905 connectors